Indirect Air Economizer 500KW | IAEC50

  • Ultra-efficient economizer units that consume zero white space and allow more power to IT

This product is currently out of stock and unavailable.

IAEC50 Features

Indirect Air Economizer 500KW
Ultra-efficient economizer units that consume zero white space and allow more power to IT
        • 7x24 telephone technical support
          Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you require is available at any given time.
        • Active Airflow Control
          Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
        • Active Alarms
          A chronological list of active alarms for the StruxureWare Data Center Expert server. The user can select an alarm to view details about that alarm and the device reporting to it.
        • Active response controls
          Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
        • Air filtration
          Removes dirt and other particulates from the intake air for cleaner supply air.
        • Automatic restart
          Returns the unit to its last operating status in the event of a power failure.
        • Building Management Systems
          Units are designed to work with the most common BMS systems including BACnet and Modbus.
        • Direct drive motors
          Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
        • Dry contact output
          Provides remote notification of failures when used with APC environmental monitoring unit or system.
        • Dual fans
          Provides fault tolerance in the event of a fan failure.
        • Dual power inputs
          (Optional) Dual power supplies for incoming power redundancy
        • Easy service access
          Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
        • Economization
          Achieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.
        • Electronic expansion valve
          Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
        • Electronically Commutated Fans
          Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
        • Fault-tolerant fan system
          In the event of a fan failure, the remaining fan(s) will continue to operate.
        • Indirect Heat Exchange
          A polymer heat exchanger allows the data center and outside airstreams to remain separated, thereby preventing contamination and humidity influences to the data center airstream.
        • Network interface
          Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
        • Pulse Powered Water Treatment System
          Eliminates the use of chemicals in the system, allowing the water to be re-used or drained without harming the environment.
        • Redundant Pumps
          Provide higher availability to installed equipment with two pumps in a 2N configuration.
        • Scroll compressors
          Utilize few moving parts for increased reliability and life expectancy.
        • Service monitoring
          All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
        • Supplemental Mechanical Cooling
          Provides extra capacity to augment economization, extending annual hours of energy savings.
        • Variable speed fans
          Variable speed fans reduce energy consumption during off-peak cooling periods.
        • Zero White Space
          All cooling equipment is placed outside the data center, allowing for valuable white space to be fully utilized for IT equipment.

Input

Input frequency

50/60 Hz

Communications & Management

Control panel

 7 " Touch Screen Display

Conformance

Approvals

CE, UL Listed

Standard warranty

1 year on-site repair or replace with factory authorized Start-Up

General

Air Flow

65280.0CFM (30808.72lps)

Compressor Type

Scroll