InRow RC, 600mm, Chilled Water, 460-480V, 60Hz | ACRC601

  • Close-coupled, chilled water cooling for medium to large data centers

  • Includes: Installation guide, Operations and maintenance manual

This product is currently out of stock and unavailable.

ACRC601 Features

InRow RC, 600mm, Chilled Water, 460-480V, 60Hz
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide, Operations and maintenance manual

InRow Chilled Water Cooling Features & Benefits

Manageability

Real-Time Capacity Monitoring

Real-time display of current and available cooling.
Microprocessor controller

Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration

Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Serviceability

Easy service access

Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Agility

Casters

Provides flexibility to move the unit to wherever cooling is required.
Scaleable densities

Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Modular design

Modular design provides scalable solutions to add cooling as demand increases.

Total Cost of Ownership

Row-based architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans

Variable speed fans reduce energy consumption during off-peak cooling periods.

Availability

Rack inlet control

Rack inlet control guarantees inlet temperature to IT equipment.
Dual A-B power inputs

Draws power from the UPS for power protection with dual feeds for redundancy.
Predictable cooling

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Active response controls

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Top and bottom chilled water connections

Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

Input

Nominal Input Voltage

480V 3PH
Input frequency

60 Hz
Input Connections

Hard Wire 4-wire (3PH + G)
Number of Power Cords

2

Communications & Management

Control panel

Multi-function LCD status and control console
Audible Alarm

Audible and visible alarms prioritized by severity

Physical

Maximum Height

78.39inches (1991mm, 199.1CM)
Maximum Width

23.62inches (600mm, 60.0CM)
Maximum Depth

42.13inches (1070mm, 107.0CM)
Rack Height

42U
Net Weight

760.0lbs. (345.45KG)
Shipping weight

892.0lbs. (405.45KG)
Shipping Height

85.29inches (2166mm, 216.6CM)
Shipping Width

33.47inches (850mm, 85.0CM)
Shipping Depth

44.75inches (1137mm, 113.7CM)
Color

Black
Units per Pallet

1.0

Conformance

Approvals

cUL Listed, CE, Industry Canada, UL Listed, VDE
Standard warranty

1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

Sustainable Offer Status

Proposition 65 Warning

Available in Documentation tab

General

Air Discharge Patterns

Horizontal
Air Flow

6000.0CFM (2831.68lps)
Condensate Pump Capacity

8.45gal/hour (0.008lps)
Intake Air

Rear Return
Minimum Water Inlet Temperature

45.0 °F (7.0 °C)
TOP