InRow RD, 300mm, Fluid Cooled, 208-230V, 60Hz | ACRD200

  • Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

  • Includes: Installation guide, Operations and maintenance manual

This product is currently out of stock and unavailable.

ACRD200 Features

InRow RD, 300mm, Fluid Cooled, 208-230V, 60Hz
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers
Includes: Installation guide, Operations and maintenance manual
  • Containment system compatible
    The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency
  • Head pressure control
    Modulates refrigerant head pressure to protect from coil freeze.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

InRow Direct Expansion Features & Benefits

Total Cost of Ownership

Variable speed fans

Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Active response controls

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Rack inlet temperature control

Reduces the risk of hot spots at the rack level
Predictable cooling

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Manageability

Real-Time capacity monitoring

Real-time display of current and available cooling.
Building management system integration

Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller

Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display

Serviceability

Easy service access

Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Agility

Modular design

Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities

Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Input

Nominal Input Voltage

208V, 230V
Input frequency

60 Hz
Input Power

4600.0Watts

Communications & Management

Control panel

Multi-function LCD status and control console
Audible Alarm

Audible and visible alarms prioritized by severity

Physical

Maximum Height

78.39inches (1991mm, 199.1CM)
Maximum Width

11.8inches (300mm, 30.0CM)
Maximum Depth

42.13inches (1070mm, 107.0CM)
Rack Height

42U
Net Weight

438.0lbs. (199.09KG)
Shipping weight

522.0lbs. (237.27KG)
Shipping Height

83.39inches (2118mm, 211.8CM)
Shipping Width

29.38inches (746mm, 74.6CM)
Shipping Depth

44.75inches (1137mm, 113.7CM)
Color

Black
Units per Pallet

1.0

Conformance

Approvals

cUL Listed, C-tick, CE, UL Listed
Standard warranty

1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

Sustainable Offer Status

Proposition 65 Warning

Available in Documentation tab

General

Air Discharge Patterns

Horizontal
Air Flow

2290.0CFM (1080.76lps)
Compressor Type

Scroll
Condensate Pump Capacity

2.6gal/hour (0.002lps)
Intake Air

Rear Return
Refrigerant Charge

5.0pounds (2.27pounds)
Return Diameter

4.84inches (123.0mm)
Supply Diameter

123.0inches (3124.0mm)